<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-27 08-38-39
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.20 MHz 5/5, 62 dBuV LOOP
Pilot RDS Phase Difference
6.9 kHz 2.9 kHz 31 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 71 kHz 19034 0,0105
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,7 dBr 5,81 dBr 7,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" LOOP " 6459 25 (Country) 1 0 1 1 --:--
RT
" - "
AF EON
92.9, 94.8, 98.3, 105.1, 106.1, 106.2 MHz -
FM Scope Max at: 71 kHz MIN: 10 kHz % above 76 kHz: 0,0105 Acquired: 2025/02/27 8.37.36 Total samples: 19034 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 7,0 dBr MIN: 4,7 dBr AVE: 5,81 dBr % above 12,2 dBr: 0,0 Last value: 6,6 dBr (2025/02/27 8.37.36) 08.24 08.26 08.28 08.30 08.32 08.34 08.36 0 2 4 6 8 Pm [dBr]